Read Procedure Basics for Endomechanical Devices and More

Review These Procedure Basics for Left Atrial Appendage Devices

Written by Curvo | Jun 10, 2021 4:00:00 AM

The left atrial appendage (LAA) is a normal part of cardiac anatomy. In most people, this small projection off the left atrium causes no issues and is a part of proper cardiac function. It may work as a decompression chamber whenever there are periods of high pressure in the left atrium during regular cardiac function.

Unfortunately due to its anatomy, it presents problems for people who are in atrial fibrillation (AF).

AF currently affects approximately 1% of the general population. However studies show its prevalence is expected to more than double in the next 15 years. In people with AF, the LAA tends to accumulate blood clots (thrombi). When these thrombi are worked loose into the vascular system, they may cause strokes. Patients with AF are 5 to 7 times more likely to experience a stroke than the general population. Of patients with AF, if they have an LAA thrombus, they have 3 times the increased stroke risk of AF patients without an LAA thrombus, regardless of treatment with blood thinners. Imaging evaluation is imperative in patients presenting with AF prior to most treatments including LAAC.

LAA Closure Is Second Fastest Growing Medical Device Market

According to a 2019 Energias Market Research release, the LAA closure market is estimated to reach $958 million by 2025. This makes it the second fastest growing medical device market and one that supply chain executives will need to monitor as not only the number of devices available for use, but also in the number of patients using the devices is expected to grow over the next 5 years. 

Occlusion and Exclusion in LAA: Two Options for Closing

There are two options for closing the LAA for patients with non-valvular atrial fibrillation: occlusion and exclusion. Occlusion is obtained by placing a device into the LAA which prevents thrombi from escaping and slowly closes the LAA over time. Exclusion is obtained by using a ligature, clip or surgical removal to close or exclude the LAA. Occlusion is typically done through endovascular access, while exclusion is typically accomplished via a thoracoscopic approach.

There are two devices currently approved for occlusion: Boston Scientific’s Watchman Device and Abbott’s Amulet Device. Both operate in the same basic fashion. The occlusion device is inserted into the chamber percutaneously in an EP lab. The device then spans the opening of the LAA and keeps thrombi from escaping while the body slowly closes the LAA using the scaffolding of the closure device.

For exclusion, there are limited options as well. The AtriClip from AtriCure is used to clip and seal the LAA. This is done using thoracoscopy and involves cutting and possible cardiac ablation. Append Medical is seeking FDA clearance for their exclusion device, which leaves a suture at the closure site, but no metal.

Medical Devices for LAA Procedures

Watchman

  • Reported 100,000 implantations by the end of 2019
  • Currently undergoing trials for an updated version for use on multiple types of LAA anatomy
  • Available at 600 US hospitals
  • Long-term costs are lower than traditional treatment with anticoagulants

Amulet

  • Garnered the CE mark in 2013 
  • Current market leading LAAC device in Europe
  • FDA approval in the US for investigational purposes
  • FDA approved the CATALYST trial in February 2020 to study Amulet effectiveness vs non-vitamin K antagonist oral anticoagulant (NOAC) drugs

AtriClip

  • Over 190,000 procedures worldwide
  • FDA approved changes to labeling in 2019 making it an exclusion device and allows the makers to claim electrical isolation 
  • Electrical isolation obtained by eliminating electrical activity through ischemic necrosis
  • LAA is resorbed by the body over time

Download the full Procedure Basics to learn more about left atrial appendage devices.